| Sign In | Join Free | My chinacomputerparts.com | 
 | 
Brand Name : NUOYINGJIAYE
Model Number : NYLD-CR
Certification : CE
Place of Origin : Xi'an, Shaanxi,China
MOQ : 1 pcs
Price : $450 to $1700 /pcs
Payment Terms : T/T
Supply Ability : 1000 pcs/ pre month
Delivery Time : 7 working days
Packaging Details : Carton, 60cm×30cm×30cm
Typical application : liquid flow measurement
Pipe Diameter : 300-3000mm
Measuring range : Customized design
Flow rate range : 0.1~10m/s
Electrical conductivity : >50μs/cm
Environment temperature : -20℃~/+60℃
Power supply : AC220V 50Hz/DC24V/3.6V
Process connection : Thread, flange(optional)
Upper And Lower Limit Alarm Liquid Flow Measurement NYLD-CR Insertion Type Electromagnetic Flowmeter
NYLD-CR Insertion Type Electromagnetic Flowmeter Working Principle
NYLL-CR insertion type electromagnetic flowmeter is a new type of flow meter developed on the basis of pipeline type electromagnetic flowmeter, which retains the advantages of pipeline type electromagnetic flowmeter on the basis of pipeline type electromagnetic flowmeter in the pipeline installation difficulties, large costs and other defects, according to the NIKURADS (NIKURADS) principle, electromagnetic method by measuring the average flow rate of fluid, so as to obtain the fluid The volume flow rate. Especially after the use of open hole with pressure, with pressure installation technology, insertion type electromagnetic flowmeter can be installed in the case of non-stop water, but also in the cast iron pipeline, cement pipeline installation. The successful development of insertion electromagnetic flowmeter, for the fluid flow detection provides a new means.
NYLD-CR Insertion Type Electromagnetic Flowmeter Technical Parameters
| Typical application | liquid flow measurement | 
| Pipe Diameter | 300-3000mm | 
| Measuring range | Customized design | 
| Flow rate range | 0.1~10m/s | 
| Electrical conductivity | >50μs/cm | 
| Straight pipe section | Front 5DN, rear 3DN | 
| Environment temperature | -20℃~/+60℃ | 
| Medium temperature | -20℃~/+130℃ | 
| Ambient Humidity | 5~100%RH | 
| Power supply | AC220V 50Hz/DC24V/3.6V | 
| Process connection | Thread, flange(optional) | 
| Pressure resistance | 1.6Mpa | 
| Sensor Material | Stainless Steel | 
| Protection level | IP67,IP68,IP65(optional) | 
| Explosion-proof grade | Exia II CT5 Ga, Exd II CT5 Gb(optional) | 
| Signal output | 4-20mA; RS485; HART; MODBUS | 
NYLD-CR Insertion Type Electromagnetic Flowmeter Design Feature
1. In the pipeline flow detection, simple installation, can not stop the flow, the site can be opened with pressure, with absolute installation advantages and price advantages.
2. Suitable for water, sewage, acid, strong alkali and other conductivity in 20cm or more liquid flow detection, changes in conductivity does not affect the change in performance, extremely strong to adapt to complex changes in fluid, especially for the supply and drainage pipeline flow measurement.
3. Flowmeter mechanical movable parts, converter using optimized design, tight structure, easy to install, converter and sensor with interchangeability, free to change the detection range of measured flow (0.5m / s ~ 10m / s).
4. It is only related to the insertion depth, so it has wide versatility and interchangeability. One model can be applied to the fluid measurement requirements of various sizes of pipes. Automatic range switching function. Flow meter in the flow range changes, the range can be automatically switched to ensure accurate measurement within the full range.
5. Forward and reverse flow calculation function. The user can choose positive metering or reverse metering (factory is positive metering).
6. Upper and lower limit alarm, empty tube alarm.
7. Power failure protection, parameters will not be lost after power failure, EEPROM can save the set parameters and accumulated values.
Small signal removal function. Users can set the lower voltage or lower flow rate through the display panel to cut out the small signal of interference.
8. The instrument applies the principle of "auto-zeroing" to eliminate electrochemical interference signals, and the zero point is self-stabilizing.
9. The converter and sensor have various protection levels and installation methods, including IP68 for submersible installation.
|   | 
| Liquid Insertion Type Electromagnetic Flowmeter NYLD - CR Limit Alarm Images | 
 IP68 Intelligent Electromagnetic Flow Meter 0.1-10m/S 4-20mA
                                                                                    
                        
                        
                        
                                                            IP68 Intelligent Electromagnetic Flow Meter 0.1-10m/S 4-20mA
                                                    
                        
                     NYLD Tubular Electromagnetic Flow Meter High Reliability Modbus Protocol
                                                                                    
                        
                        
                        
                                                            NYLD Tubular Electromagnetic Flow Meter High Reliability Modbus Protocol
                                                    
                        
                     1.6MPa 2.5Mpa Mag Water Flow Meter Nominal Diameter Electromagnetic
                                                                                    
                        
                        
                        
                                                            1.6MPa 2.5Mpa Mag Water Flow Meter Nominal Diameter Electromagnetic
                                                    
                        
                     Flange Type Electromagnetic Flow Meter 1Mpa Forward Reverse
                                                                                    
                        
                        
                        
                                                            Flange Type Electromagnetic Flow Meter 1Mpa Forward Reverse
                                                    
                        
                     IP68 Electromagnetic Water Meter DN40 DN300 High Measurement Accuracy
                                                                                    
                        
                        
                        
                                                            IP68 Electromagnetic Water Meter DN40 DN300 High Measurement Accuracy
                                                    
                        
                     NYLD Pipeline Type Electromagnetic Flow Meter For Liquid Measurement
                                                                                    
                        
                        
                        
                                                            NYLD Pipeline Type Electromagnetic Flow Meter For Liquid Measurement
                                                    
                        
                     316SS Insertion Electromagnetic Flowmeter ABS PTFE Lining IP67
                                                                                    
                        
                        
                        
                                                            316SS Insertion Electromagnetic Flowmeter ABS PTFE Lining IP67
                                                    
                        
                     Soy Sauce Electromagnetic Flow Meter RS485 316L Electromagnetic Flow Switch
                                                                                    
                        
                        
                        
                                                            Soy Sauce Electromagnetic Flow Meter RS485 316L Electromagnetic Flow Switch
                                                    
                        
                     1Mpa 2.5Mpa 4Mpa Electromagnetic Flow Transmitter 15mm To 800mm
                                                                                    
                        
                        
                        
                                                            1Mpa 2.5Mpa 4Mpa Electromagnetic Flow Transmitter 15mm To 800mm
                                                    
                        
                     Slurry type meteelectromagnetic flow meter for mud measurement
                                                                                        
                                                        
                        
                        
                        
                                                            Slurry type meteelectromagnetic flow meter for mud measurement